- Start engine. Check voltage at generator connector terminal L. If voltage is more than 8 volts, go to next step. If voltage is 8 volts or less, go to step 5).
- Check voltage at BAT terminal of generator (if accessible). If voltage is more than 8 volts, go to next step. If voltage is 8 volts or less, go to step 6).
- Start engine and run at fast idle. Ensure all accessories are off. Check battery voltage. If voltage is 13.3-15.5 volts, go to next step. If voltage is not 13.3-15.5 volts, go to step 7).
- Load check generator. Load test battery. Repair as needed. Recheck charging system. See CHARGING SYSTEM CHECK under TROUBLE SHOOTING.
- Check for open or poor connections at generator connector terminal "L" and PCM connector C2 terminal No. 35 (Red wire). Repair as needed. Recheck charging system.
- Repair open circuit between battery and generator terminal BATT. Recheck charging system.
- Repair or replace generator. Recheck charging system.