30-Minute Learn Procedure
Use this procedure after replacing the Passkey® III (PK3) keys, theft deterrent control module or PCM.
NOTE:
This procedure is not available on vehicles equipped with option code Z49 or BAE.
NOTE:
If replacing a theft deterrent control module with an GM SPO replacement part, perform the procedure to setup a new theft deterrent control module prior to the 30-minute relearn procedure.
- With a master Passkey® III key (Black), turn ignition on, with engine off.
- Observe the SECURITY telltale. After about 10 minutes, the telltale will turn off.
- Turn OFF ignition, and wait 5 seconds.
- Repeat steps 1 through 3 for 2 more times for a total of 3 cycles or 30 minutes.
- With a master Passkey® III key, start engine. The vehicle has now learned the key transponder information and PCM has now learned the fuel continue password.
- Using scan tool, clear any DTCs.
NOTE: