Electrical Check: Electrovalves
- Partially disconnect top wires (82A, 82B, and 82C) to each electrovalve without breaking electrical contact. Connect voltmeter to ground and to exposed terminal.
- Voltage for each wire should be equal to battery voltage. If not, check problem wire for shorts. Disconnect bottom wire (82, 83, or 84) to electrovalve being tested. Connect a jumper wire in place of it on electrovalve.
- Ground other end of jumper wire. There should be a "clicking" sound from electrovalve. If not, disconnect other wire from electrovalve.
- Connect leads of ohmmeter to terminals on electrovalve. Resistance should be about 40 ohms. If resistance is infinity or close to it, replace electrovalve.