Ignition Module Test
Connect the ignitor, lamp, and battery. See Fig 1. Using a dry cell battery or continuity tester, apply voltage to the signal input terminal of the ignitor unit. Lamp should light when voltage is applied, and go out when voltage is removed. If not, ignitor is bad.
NOTE:
This test can only determine when ignitor is bad. Even if ignitor tests out as good, it could still be defective.