DRB-II Key Functions
- YES or Down Arrow & NO or Up Arrow Keys will move lines on screen up or down allowing user to choose an item or scroll through all selections available.
- F1 & F2 Keys Keys are used to scroll through sensor displays.
- ATM Key Key will return user to previous screen.
- ENTER Key Allows user to select a test or display. Flashing arrow must be on display user wishes to select. Pressing ENTER in sensor state will cause display to change from a 3-line display to a 1-line display.
- F3 Key Key is used to display a help screen. This key may be used at any time.
- Number Keys Keys are used for choosing a display or test by number for test or display.
- READ/HOLD Key Key is used to freeze any sensor display.
- MODE & ATM Keys Pressing MODE and ATM keys at same time will cause DRB-II to reset to copyright screen.