DTC P0125: Closed Loop Temperature Not Reached: Description
Engine coolant temperature is monitored for 10 minutes after engine is started when battery voltage is more than 10.4 volts. DTC will set when engine coolant temperature does not increase to more than 60°F after 10 minutes. This is a 2-trip fault. Possible causes are: low coolant level or defective thermostat.