Compressor Assembly
- Remove flexible mounts, adapters, cover, and gaskets from first stage housing. Remove regulator and "O" ring from second stage housing. Discard ring.NOTE: Do not lubricate unit as it is designed to operate dry. Always hold bolts stationary and remove nuts during disassembly. Do not turn bolt heads. Short bolts have a second (hidden) nut between reservoir flange and second stage housing.