Engine Controls - Sensor Operating Range Charts: Introduction
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.
NOTE:
Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
COOLANT TEMPERATURE SENSOR RESISTANCE
| Temperature °F (°C) |
Ohms |
| 212 (100) |
177 |
| 194 (90) |
241 |
| 176 (80) |
332 |
| 158 (70) |
467 |
| 140 (60 |
667 |
| 122 (50) |
973 |
| 113 (45) |
1188 |
| 104 (40) |
1459 |
| 95 (35) |
1802 |
| 86 (30) |
2238 |
| 77 (25) |
2796 |
| 68 (20) |
3520 |
| 59 (15) |
4450 |
| 50 (10) |
5670 |
| 41 (5) |
7280 |
| 32 (0) |
9420 |
| 23 (-5) |
12,300 |
| 14 (-10) |
16,180 |
| 5 (-15) |
21,450 |
| -4 (-20) |
28,680 |
| -22 (-30) |
52,700 |
| -40 (-40) |
100,700 |
FUEL INJECTOR SOLENOID RESISTANCE
| Test Point |
Ohms |
| Between Injector Terminals |
Greater Than 1.2 |
IDLE AIR CONTROL VALVE (IACV) RESISTANCE
| Wire Color (Connector Terminal) |
Ohms |
| Green/White (A) & Green/Black (B) |
40-80 |
| Blue/White (C) & Blue/Black (D) |
40-80 |
MANIFOLD ABSOLUTE PRESSURE (MAP) SENSOR VOLTAGE
| Altitude Feet (Meters) |
Volts |
| 1000-2000 (305-610) |
3.6-5.2 |
| 2000-3000 (610-914) |
3.5-5.1 |
| 3000-4000 (914-1219) |
3.3-5.0 |
| 4000-5000 (1219-1524) |
3.2-4.8 |
| 5000-6000 (1524-1829) |
3.0-4.6 |
| 6000-7000 (1829-2133) |
2.9-4.5 |
| 7000-8000 (2133-2438) |
2.8-4.3 |
| 8000-9000 (2438-2743) |
2.6-4.2 |
| 9000-10,000 (2743-3048) |
2.5-4.0 |
O2 SENSOR VOLTAGE
| Condition |
Volts |
| Lean |
0.1 |
| Rich |
0.9 |
THROTTLE POSITION SENSOR (TPS) VOLTAGE
| Application |
Volts |
| Closed Throttle |
.4-1.25 |
| Full Throttle |
4.8 |