Code 44, Oxygen (O2) Sensor CKT Lean Exhaust Indication: Notes
The ECM supplies a voltage of about .45 volt between terminals D7 and D6. If measured with 10-megohm voltmeter, voltage reading may be as low as .32 volt.
The oxygen sensor varies voltage within range of approximately .1 volt (lean exhaust) to 1.0 volt (rich exhaust). The sensor is like an open circuit and produces no voltage when sensor temperature is less than 600°F (316°C). An open sensor circuit or cold sensor causes open loop operation.
Code 44 is set when oxygen (O2) sensor voltage on the signal wire remains less than .2 volt for about one minute, the system is operating in closed loop, and Code 33 or 34 is set.