Code 45, Oxygen (O2) Sensor CKT (Rich Exhaust Indication): Notes
The ECM supplies voltage of about .45 volt between terminals D7 and D6. If measured with 10-megohm digital voltmeter, voltage reading may be as low as .32 volt.
The oxygen sensor varies voltage within range of approximately .1 volt (lean exhaust) to 1.0 volt (rich exhaust). The sensor is like an open circuit and produces no voltage when sensor temperature is less than 600°F (316°C). An open sensor circuit or cold sensor causes open loop operation.
Code 45 is set when O2 sensor voltage on circuit No. 412 remains greater than .8 volt for one minute, and system is in closed loop.