Test Description
The numbers below refer to the step numbers in the diagnostic procedures.
- 2
Other secondary air injection DTCs should be diagnosed first if set. If the HO2S voltage remains below 50 mV for approximately 5 seconds, the system is operating normally. - 4
Listen for a running motor. Command both the ON and OFF states. Repeat the commands as necessary. - 5
Listen for a click when the device operates. Command both ON and OFF states. Repeat the commands as necessary. - 6
This step begins to eliminate an airflow problem. - 9
This step tests for a vacuum leak at the valve. - 10
This step tests the operation of the valve. - 12
This step tests the control circuit for operation. - 13
This step by-passes the relay to test pump operation. - 15
This step tests the control circuit for operation. - 18
This step eliminates the relay and the control circuit as a cause for continuous pump operation. - 19
This step tests the control circuit for operation. - 40
The pump may have failed from another fault. If the pump operates without a command, refer to step 18. - 42
If the HO2S voltage remains below 50 mV for approximately 5 seconds, the system is operating normally.