Test Description
The number below refers to the step number in the diagnostic procedures.
- 2 - Listen for an audible click when the cooling fan 1 relay operates. Command both the ON and OFF states. Repeat the commands as necessary.
- 3 - Listen for an audible click when the cooling fan 2 and cooling fan 3 relays operate. Command both the ON and OFF states. Repeat the commands as necessary.
- 4 - Tests for voltage at the coil side of the cooling fan 1 relay. The COOL FAN #1 fuse supplies battery positive voltage to the coil side of the cooling fan 1 relay.