Test Description
The numbers below refer to the step numbers on the diagnostic table.
- 2 - This step checks whether there is communication between PCM and a scan tool device. If PCM is unable to provide serial data to the scan tool, there will be no MIL control.
- 3 - If other Instrument Panel Cluster (IPC) functions are not working correctly check for an open GAUGE fuse or for a lack of power and ground to IPC.
- 4 - This step checks for an open MIL control circuit or for an internal PCM failure.
- 5 - An open fuse determines if a voltage is constantly being applied to the control circuit.
MIL Illumination
- MIL will illuminate with ignition switch in RUN position and engine not running.
- MIL will turn OFF when engine is started.
- MIL will remain illuminated if self-diagnostic system has detected a malfunction.
- MIL may turn OFF if malfunction is not present.
- If MIL is illuminated and then the engine stalls, MIL will remain illuminated so long as the ignition switch is in RUN position.
- If MIL is not illuminated and engine stalls, MIL will not illuminate until the ignition switch is cycled OFF, then to RUN position.
Perform the Diagnostic System Check - Engine Controls, when the following conditions are present:
- MIL does not illuminate when ignition switch is turned to RUN position. See MIL OPERATION .
- MIL remains illuminated while engine is running.
- MIL is flashing while engine is running.
- A driveability symptom is determined.