Installation Procedure
- Install the fuel pressure regulator to the fuel rail
- Install the fuel pressure regulator retaining bolt.
Tighten: Tighten the retaining bolt to 10 N.m (89 lb in).
- Connect the vacuum pipe to the fuel pressure regulator.
- Connect the negative battery cable. Refer to Battery Negative Cable Disconnect/Connect Procedure in Engine Electrical.
- Inspect for leaks using the following procedure:
- Turn ON the ignition, with the engine OFF for 2 seconds.
- Turn OFF the ignition for 10 seconds.
- Turn ON the ignition.
- Inspect for fuel leaks.
- Place the shop towel into a suitable storage container.
IMPORTANT:
Lubricate the O-ring with clean engine oil before installation.
NOTE:
Refer to Fastener Notice in Cautions and Notices.