Installation Procedure
CAUTION:
Use care when handling the coolant sensor. Damage to the coolant sensor will affect the operation of the fuel control system.
- If you are reinstalling the original sensor, or if you are installing a NEW sensor without a sealer, coat the threads with sealant. Refer to Adhesives, Fluids, Lubricants, and Sealers .
- Install the ECT sensor and tighten to 20 N.m (15 lb ft).
- If equipped with RPO M86, connect the engine harness electrical connector (3) to the ECT sensor.
- If equipped with RPO MN5, connect the engine harness electrical connector (3) to the ECT sensor.
- Fill the cooling system. Refer to Cooling System Draining and Filling (GE 47716 Fill) or Cooling System Draining and Filling (Static Fill LNF) or Cooling System Draining and Filling (Static Fill LE5, L61) .
CAUTION:
Refer to Component Fastener Tightening Caution
.