Parasitic Draw

Divide the reserve capacity by 4 (Amp hour rating by 2.4).
Compare this to the multimeter milliamp reading taken in the previous step. The parasitic current drain should not exceed this number.

Example: If a battery has a reserve capacity of 100 minutes, (60 A/H) the current drain should not exceed 25 mA.