LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Pontiac >> 2009 >> Torrent Base, AWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls And Fuel - 3.4L - Introduction >> Repair Instructions >> Metal Collar Quick Connect Fitting Service >> Removal Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Removal Procedure

    Fig 1: View Of Quick-Connect Fitting Retainer (Metal Collar)
    GM730809Courtesy of GENERAL MOTORS CORP.
  1. Relieve the fuel system pressure before servicing any fuel system connection. Refer to the Fuel Pressure Relief (Without CH 48027) or Fuel Pressure Relief (With CH 48027) .
  2. Remove the retainer from the quick-connect fitting.
  3. Fig 2: Blowing Dirt Out Of Fitting (Metal Collar)
    GM12776Courtesy of GENERAL MOTORS CORP.
    WARNING: Refer to Safety Glasses Warning .
  4. Blow dirt out of the fitting using compressed air.
  5. Fig 3: View Of Quick Connect Locking Tabs (Metal Collar)
    GM12780Courtesy of GENERAL MOTORS CORP.
  6. Choose the correct tool from the J 37088-A  for the size of the fitting. See Special Tools . Insert the tool into the female connector, then push inward in order to release the locking tabs.
  7. Fig 4: View Of Quick Connect Locking Tabs (Metal Collar)
    GM12782Courtesy of GENERAL MOTORS CORP.
    WARNING: Refer to Relieving Fuel Pressure Warning .
  8. Pull the connection apart.
  9. Use a clean shop towel in order to wipe off the male pipe end.
  10. Inspect both ends of the fitting for dirt and burrs. Clean or replace the components as required.