Coolant Temperature Sensor
Remove CU connector plug. Connect a ohmmeter between terminal No. 13 and ground. Compare ohmmeter readings to specifications.
TEMPERATURE SENSOR II SPECIFICATIONS
| Temperature |
Ohms (+/- 10%) |
| 50°F (10°C) |
3300-4100 |
| 68°F (20°C) |
2200-2800 |
| 104°F (40°C) |
1000-1300 |
| 176°F (80°C) |
290-350 |
| 212°F (100°C) |
160-210 |