LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Porsche >> 1988 >> 944 Base, Standard >> Repair and Diagnosis >> Engine Performance >> System >> DME Digital Engine Control >> Diagnosis & Testing >> Cu Power Supply
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Cu Power Supply

  1. Disconnect CU connector. Connect positive voltmeter lead to terminal No. 35 of CU harness connector. Connect negative test lead to terminal No. 5 of CU harness connector. Turn ignition on. Voltmeter should read battery voltage.
  2. Connect voltmeter positive test lead to terminal No. 18 of CU harness connector. Connect negative test lead to terminal No. 5 of CU harness connector. Turn ignition on. Voltmeter should read battery voltage.
  3. If no voltage is available, remove DME power relay. Using a jumper wire, connect terminals No. 30 and 87. Repeat voltage checks in steps 1) and 2). On 944 series, connect voltmeter between terminals No. 3 of 9-pin connector and ground. If no voltage is present, check battery and related circuits.