Ignition Coil Primary Resistance
- Ensure ignition switch is off. Disconnect wires from primary terminals of ignition coils to isolate them from system.
- Set ohmmeter at x1 scale. Connect ohmmeter leads to both primary terminals. Reading should be .4-.6 ohm. If reading is not as specified, replace ignition coil.