Thermostatic Valve

Disconnect thermostatic valve hoses. Blow through valve. Valve should be closed when temperature is below 110°F (43°C) on on-off and two-port and 68°F (20°C) on proportional systems. Valve should be open when engine temperature is above that listed. Replace thermostatic valve if defective.