Trionic 7, Mode 06
TRIONIC 7, MODE 06 DESCRIPTION
| Test ID (Hex) | Test limit type and Comp ID (Hex) | Description | Decimal range | Hex range |
|---|---|---|---|---|
| TID 13 1 mm leak check Saab 9- 3 2000MY-2003MY Saab 9-5 2000MY-2001MY |
00 | EVAP monitor, small leak factor. | 0 to 65535 | 0000 to FFFF |
| 01 | EVAP monitor, large leak factor. | 0 to 65535 | 0000 to FFFF | |
| The same value is reported in CIDs 00 and 01. When a large leak is present, both CIDs will show "Fail". | ||||
| TID 13 0.5 leak check Saab 9-5 2002MY- |
00 | EVAP monitor, very small leak factor. | 0 to 65535 | |
| 01 | EVAP monitor, small leak factor. | 0 to 65535 | 0000 to FFFF | |
| 02 | EVAP monitor, large leak factor. | 0 to 65535 | 0000 to FFFF | |
| The same value is reported in CIDs 00, 01 and 02. When a large leak is present, all CIDs will show "Fail". | ||||
| TID 14 | 00 | EVAP pressure sensor, number of flank shifts with amplitude above limit. | 0 to 65535 | 0000 to FFFF |
| 01 | EVAP pressure sensor offset, time for signal out of limits. Value is presented in milliseconds | 0 to 65535 msec | 0000 to FFFF | |
| TID 15 | 00 | Brake switch, number of decelerations | 0 to 65535 | 0000 to FFFF |
| TID 1D | 80 | Thermostat/ECT sensor test. Actual ECT reading at time of diagnostic is shown. Minimum limit. | 0 to 65535 °C | 0000 to FFFF |
| 01 | Thermostat/ECT sensor test. Actual ECT reading at time of diagnostic is shown. Maximum limit. | 0 to 65535 °C | 0000 to FFFF | |
| TID 1E | 80 | Fuel tank pressure sensor adoption | 0 to 65535 | 0000 to FFFF |
| Test limit type and Comp ID description | ||||
| Parameter name | bit | Description | ||
| Component ID | 0 - 6 | Component ID - manufacturer specified - necessary when multiple components or systems are present on the vehicle and have the same definition of Test ID. If the same test is performed on more than one component, multiple test results shall be reported for that Test ID. For example, a test for bank 1 catalyst can be the same as a test for a bank 2 catalyst, or a test for a pre-catalyst oxygen sensor can be the same as a test for a post-catalyst oxygen sensor. In either case, a request for a single Test ID would result in two test results being reported with different Component IDs. |
||
| Test Limit Type | 7 | Most significant bit indicates type of test limit, where: 0 - test limit is maximum value - test fails if test value is greater than this value. 1 - test limit is minimum value - test fails if test value is less than this value. |
||