To fit
IMPORTANT:
Do not
spray any kind of contact spray onto the internal contact pins/sleeves. Do not
blow clean with compressed air.
- Check the gasket on the new control module. Fit it carefully by holding the edges with one hand an slowly lowering it so that the valves and contacts are in the right place.IMPORTANT: Grip the control module by its edges only when removing/fitting. The control module can be damaged by pressure on the top.
- Fasten the bolts and torque tighten them in the illustrated order.
Tightening torque 3 Nm +/- 0.3 (2.15 +/- 0.21 lbf ft)
- Fit the bracket on the hydraulic unit.
- Fit ESP UNIT WITH CONTROL MODULE .
- Perform SPARE PARTS PROGRAMMING, ESP .