Code 17, Enable Relay Coil Circuit Grounded: Notes
ABS Control Module (ACM) receives battery voltage when system enable relay contacts are closed. Voltage at ACM terminal "A" provides power for ABS motors and solenoids. If ACM detects fault in this circuit, it will not disable ABS operation, but will flash ANTI-LOCK warning light.