Code 44: Lean Exhaust Indication: Notes
NOTE:
Some models engines are equipped with 2 oxygen sensors. On these models, Code 44 will set if the left sensor circuit is lean. Code 64 will set if the right sensor circuit is lean. Use this chart for Code 64 also and perform tests for applicable sensor.
O2 sensor acts like an open sensor circuit and produces no voltage when exhaust temperature is less than 600°F (316°C). An open sensor circuit or cold sensor causes "open loop" operation. On models with 2 oxygen sensors, Code 44 will reflect a lean left O2 sensor; Code 64 will indicate a lean right O2 sensor. Perform test procedures for right or left sensor as necessary.
NOTE:
Test number refers to number on diagnostic chart.
- Checks to see if O2 sensor is registering a lean condition. Code 44 is set when O2 sensor voltage signal at control module is low (less than .3 volt) for a precalibrated period and system is operating in "closed loop".