Knock Sensor (KS)
Disconnect knock sensor harness connector. Using an ohmmeter, measure knock sensor resistance between sensor terminal and engine block. Resistance should be 3300-4500 ohms. Connect DVOM between sensor terminal and ground. Set voltmeter to 2-volt AC scale. Start and idle engine. Tap on engine block near sensor. A signal should be indicated on voltmeter. If no signal is indicated, replace knock sensor. Also, see TIMING CONTROL SYSTEMS under IGNITION SYSTEM. If a code is present, see TESTS W/CODES article in this section.