Intermittent Failures
Intermittent failures cause MIL to flicker or glow and go out about 10 seconds after intermittent fault goes away. Corresponding DTC, however, will be retained in PCM/VCM memory. If related fault does not reoccur within 50 engine starts, trouble code will be erased from control module memory. Intermittent failures may be caused by sensor, connector or wiring related problems. See INTERMITTENTS in TESTS W/O CODES article.
NOTE:
OBD II vehicles have options available in the scan tool DTC mode to display enhanced information available. However, to fully utilize information and procedures requires the use of a Tech 1 scan tool. See tester operator's manual for additional information.
The following are Tech 1 scan tool sub-menus in the DTC INFO and SPECIFIC DTC modes: