Oxygen Sensor: Installation
- Whenever an oxygen sensor is removed, coat threads with anti-seize compound before it is reinstalled. New oxygen sensors already have this compound applied to threads.
- Install oxygen sensor in exhaust pipe. Tighten sensor to 30 ft. lbs. (41 N.m). Reconnect electrical connector to oxygen sensor. Reconnect negative battery cable.