Fuel Pump Relay By-Pass Procedure
- If fuel pump will not energize, relay may be by-passed to test fuel pump and related wiring. Turn ignition off. Disconnect fuel pump relay connector. Using a fused jumper wire, connect jumper wire between fuel pump feed terminal and fuel pump relay ignition feed circuit.
- If fuel pump runs and relay tests okay, check for faulty connections at relay. If fuel pump does not run, check for faulty wiring between relay and fuel pump or replace defective fuel pump.