High/Low Pressure Cut-Out Switch
High/low pressure cut-out switch is a dual-pressure switch located forward of left front strut tower on liquid line. Switch contains 2 sets of contacts. PCM disengages compressor clutch if either set of contacts open.
PCM will de-energize A/C clutch relay when discharge pressure is greater than 380-401 psi (26.7-28.2 kg/cm2 ) and energize A/C clutch relay when discharge pressure is 200-251 psi (14.1-17.6 kg/cm2 ). PCM will energize cooling fan relay for 180 seconds after A/C clutch relay is de-energized because of pressure switch activation. PCM will de-energize A/C clutch relay if discharge pressure is less than 40 psi (2.8 kg/cm2 ).