Crankshaft Position (CKP) Sensor Short & Resistance Checks
- Set DVOM on 2000-ohm scale. Connect DVOM leads to CKP sensor connector located on side of engine block. Turn ignition off. Disconnect ignition control module harness connectors. Measure resistance between CKP sensor terminals at ignition control module connector.
- CKP sensor resistance should be 500-900 ohms. If resistance is not as specified, replace CKP sensor. If sensor resistance is within specification, go to next step.