Transaxle Range Switch: Adjustment
NOTE:
While adjusting the transaxle range switch, always rotate the switch towards the engine to achieve continuity. A diagnostic trouble code DTC P0706 could result if this procedure is not followed.
NOTE:
Digital volt/ohm meter (DVOM) with audible continuity test is preferred. Do not stick the probe in the transaxle range switch terminal hole; use male terminals on the transaxle range switch or faulty readings could occur.
- Place the transaxle in Drive (D). Use an ohmmeter or continuity tester to check for continuity across terminals on the selector switch. See Figure . Rotate the transaxle range switch from the left fender towards the engine until continuity is achieved.
- Tighten the switch-to-case bolts to specification. See TORQUE SPECIFICATIONS . After switch-to-case bolts have been tightened, check continuity.
- Connect the transaxle range switch harness connectors.
- Install the air cleaner and duct assembly.
- Using a scan tool, ensure each gear position reads correctly while manually moving through all gears.