Circuit Description
Oxygen sensor responds to oxygen content in exhaust manifold. Sensor voltage is read by the PCM to determine a rich/lean O2S1 signal used to adjust injector pulse width. Normal sensor reading will fluctuate between 10-999 mV. DTC will set when sensor signal has not switched greater than 10 times within a 100 second test when engine speed is between 1500-3000 RPM, loop status is closed, calculated airflow is greater than 7 gm/s, commanded A/F ratio is 14.7:1, no CAM, CKP, ECT, EGR, EVAP, fuel trim, IAT, MAP, misfire, O2S1, system voltage or TP sensor DTCs not set.