Conditions For Running DTC
- DTCs P0105, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0122, P0123, P0125, P0131, P0132, P0133, P0134, P0135, P0452, P0453, P0502, P0503, P0601, P0602, P1621, P1624, P1683 are not set.
- Engine is running.
- EVAP vent solenoid is commanded ON, closed.
- EVAP purge solenoid is commanded OFF, closed.
- Fuel level is 15-85 percent.
- BARO is greater than 75 kPa.
- ECT and IAT are 39-86°F (4-30°C) at engine start-up.
- ECT and IAT are within 15°F (8°C) of each other.
- Vehicle speed is less than 70 MPH.
- TP sensor parameter is 10-35 percent.
- DTC P1441 diagnostic runs once per ignition cycle, usually for 30 seconds if no faults exist, during the EVAP diagnostic system test.