Installation Procedure
- With the throttle in the closed position, install the TP sensor and seal.
- Install the TP sensor screw.
Tighten: Tighten the TP sensor screw to 2 N.m (18 lb in).
- Connect the TP sensor harness connector (2).
- Install the air cleaner outlet resonator. Refer to Air Cleaner Outlet Resonator Replacement .
NOTE:
Refer to Fastener Notice in Cautions and Notices.
IMPORTANT:
Install a new TP sensor screw when replacing the TP sensor.