Installation Procedure
- Install the TMAP sensor into the intake manifold.
Tighten: Tighten the bolt to 10 N.m (89 lb in).
- Connect the TMAP sensor harness connector.
IMPORTANT:
Use the new TMAP sensor seal provided with the new TMAP sensor.
NOTE:
Refer to Fastener Notice
in Cautions and Notices.