Installation Procedure
- Install the MAF sensor into the air cleaner housing.
- Secure the MAF sensor to the air cleaner housing with the 2 fasteners.
Tighten: Tighten the 2 fasteners to 2 N.m (18 lb in).
- Connect the MAF sensor electrical connector.
NOTE:
Refer to Fastener Notice
in Cautions and Notices.