Installation Procedure
NOTE:
Refer to Fastener Notice
in Cautions and Notices.
IMPORTANT:
DO NOT apply thread sealant to the sensor threads. The sensor threads are coated at the factory and applying additional sealant affects the sensors ability to detect detonation.
- Install the KS into engine block.
Tighten: Tighten the KS to 31 N.m (23 lb. ft.).
- Connect the KS wiring harness connector to the knock sensor.
- Install the lower left intake manifold. Refer to Intake Manifold Spacer Replacement and Intake Manifold Replacement - Lower Left in Engine Mechanical - 3.5L (L66).