Installation Procedure
- Make sure the MAP sensor mounting surface is clean. Install the MAP sensor with the new O-ring and attachment bolt (6).
Tighten: Tighten the manifold absolute pressure sensor screw to 4 N.m (35 lb. in.).
- Connect the MAP sensor harness connector. Push the connector in until the lock position is felt, then pull back to confirm engagement.
NOTE:
Refer to Fastener Notice