Circuit Description
DTC P0125
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0125 | If THW or THA less than -6.6°C (20°F) At Engine Start, 20 Min. Or More After Starting Engine, Engine Coolant Temp. Sensor Value Is 20°C (68°F) Or Less (2 Trip Detection Logic) |
|
| If THW and THA Is Between -6.6°C (20°F) And 10°C (50°F) At Engine Start, 5 Min. Or More After Starting Engine, Engine Coolant Temp. Sensor Value Is 20°C (68°F) Or Less (2 Trip Detection Logic) | ||
| If THW and THA Greater Than 10°C (50°F) At Engine Start, 2 Min. Or More After Starting Engine, Engine Coolant Temp. Sensor Value Is 20°C (68°F) Or Less (2 Trip Detection Logic) |