Service Data
SERVICE DATA SPECIFICATIONS
| Starter Assy. Specified Current |
90 A or less at 11.5 V |
| Starter Relay Specified Condition |
| 1 - 2 |
Continuity |
| 3 - 5 |
No Continuity |
| Battery Except Maintenance-Free Battery Standard Specific Gravity |
1.27 to 1.29 at 20°C (68°F) |
| Battery Voltage At 20°C (68°F) |
12.5 to 12.9 V |
| Voltage Regulator |
| Regulating Voltage |
12.9 to 14.9 V |
| Standard Amperage |
10 A or less |
| Starter Armature Assy. Commutator Length |
| Standard |
3.1 mm (0.122 in.) |
| Minimum |
3.8 mm (0.150 in.) |
| Starter Commutator Assy. Brush Length |
| Standard |
9.0 mm (0.354 in.) |
| Minimum |
4.0 mm (0.158 in.) |
| Starter Armature Assy. Snap Ring Length Maximum |
5.0 mm (0.197 in.) |
| Generator Rotor Assy. Coil Resistance At 20°C (68°F) |
2.1 to 2.5 W ohm |
| Generator Rotor Assy. Slip Ring Diameter |
| Standard |
14.2 to 14.4 mm (0.559 to 0.567 in.) |
| Minimum |
12.8 mm (0.504 in.) |
| Generator Brush Holder Assy. Exposed Brush Length |
| Standard |
9.5 to 11.5 mm (0.374 to 0.453 in.) |
| Minimum |
4.5 mm (0.177 in.) |