Monitor Strategy
MONITOR STRATEGY REFERENCE
| Related DTCs | P0101: Mass air flow meter rationality |
| Required sensors/ components (Main) | Mass air flow meter |
| Required sensors/ components (Related) | Engine speed sensor, engine coolant temperature sensor and throttle position sensor |
| Frequency of operation | Continuous |
| Duration | 10 seconds: High voltage 6 seconds: Low voltage |
| MIL operation | 2 driving cycles |
| Sequence of operation | None |