Typical Enabling Conditions

TYPICAL ENABLING CONDITIONS

Monitor runs whenever these DTCs not present P0011, P0012, P0021, P0022: VVT system
P0100 - P0103: MAF sensor
P0110 - P0113: IAT sensor
P0115 - P0118: ECT sensor
P0120 - P2135: TP sensor
P0171 - P0175: Fuel trim
P0300 - P0304: Misfire
P0335: CKP sensor
P0340: CMP sensor
P0351 - P0354: Igniter
P0450, P0452, P0453: Canister pressure sensor
P0500: VSS sensor
Atmospheric pressure (absolute pressure) 70 to 110 kPa (525 to 825 mmHg)
Battery voltage 10.5 V or more
Vehicle speed Below 4km/h (2.5 mph)
Ignition switch OFF
Soak time (ignition switch OFF time) 5, 7 or 9.5 hours
Engine coolant temperature 4.4 to 35°C (40 to 95°F)
Intake air temperature 4.4 to 35°C (40 to 95°F)
Canister pressure sensor malfunction (P0450, P0452, P0453) Not detected
Purge VSV Not operated by scan tool
Vent valve Not operated by scan tool
Leak detection pump Not operated by scan tool
When both conditions below are met: Condition 1 and 2 are met before key off
1. Duration that vehicle has been driven 5 minutes or more
2. EVAP purge operation Performed

Key-off monitor sequence 1 to 6 

1. Atmospheric pressure measurement 

ATMOSPHERIC PRESSURE MEASUREMENT

Next sequence is run if the following condition is met: -
Atmospheric change for 10 seconds Within 0.3 kPa (2.25 mmHg) in 1 second

2. First reference pressure measurement 

FIRST REFERENCE PRESSURE MEASUREMENT

Next sequence is run if the following conditions are met: -
EVAP pressure just after reference pressure measurement start -1 kPa (755 mmHg) or lower
Reference pressure -4.3 to -1.2 kPa (730 to 753 mmHg)
Reference pressure Saturated within 60 seconds

3. Vent valve stuck closed check 

VENT VALVE STUCK CLOSED REFERENCE

Next sequence is run if following condition is met -
EVAP pressure change after vent valve is ON 0.3 kPa (2.25 mmHg) or more

4. Vacuum introduction 

VACUUM INTRODUCTION

Next sequence is run if following condition is met -
EVAP pressure Saturated within 12 minutes

5. Purge VSV stuck closed check 

PURGE VSV STUCK CLOSED

Next sequence is run if following condition is met -
EVAP pressure change after purge valve is open 0.3 kPa (2.25 mmHg) or more

6. Atmospheric pressure 

ATMOSPHERIC PRESSURE REFERENCE

EVAP monitor is complete if the following condition is met -
Atmospheric pressure difference between sequence 1 and 6 Within 0.3 kPa (2.25 mmHg)