Related DTCS
DTCS REFERENCE
| DTC | Monitoring Item |
|---|---|
| P043E | Reference orifice clogged (built into canister pump module) |
| P043F | Reference orifice high-flow (built into canister pump module) |
| P0441 |
|
| P0451 |
|
| P0452 | Canister pressure sensor (built into canister pump module) voltage low |
| P0453 | Canister pressure sensor (built into canister pump module) voltage high |
| P0455 | EVAP gross leak |
| P0456 | EVAP small leak |
| P2401 | Leak detection pump stuck OFF (built into canister pump module) |
| P2402 | Leak detection pump stuck ON (built into canister pump module) |
| P2419 | Vent valve stuck closed (built into canister pump module) |
| P2420 | Vent valve stuck open (vent) (built into canister pump module) |
| P2610 | Soak timer (built into ECM) |
If any EVAP system DTCs are set, the malfunctioning area can be determined using the table below.
NOTE:
If the reference pressure difference between the first and second checks is greater than the specification, all the DTCs relating to the reference pressure (P043E, P043F, P2401, P2402 and P2419) are stored.