System Testing
CAUTION:
Do not inhale fuel vapor when blowing into fuel evaporation hoses. Fuel vapors can be a health hazard.
With filler cap removed, disconnect vent hose between carbon canister and fuel tank. Blow air toward canister and check that air flows freely into canister. Blow air toward fuel tank and check that air flows into tank with a slight resistance caused by the 2-way valve.