Airflow Meter Testing
Remove rubber cover from electrical connector on airflow meter. Leave connector connected. Connect volt/ohmmeter between terminals and record readings. See AIRFLOW METER SPECIFICATIONS table. If readings are not to specifications, check electrical wiring. If wiring is okay, replace airflow sensor.
NOTE:
DO NOT start engine unless specified. Place the ignition switch in the OFF or ON position as indicated.
NOTE:
Airflow meter test specifications for Justy not available from manufacturer.
AIRFLOW METER SPECIFICATIONS
| Ignition Switch | Wire Colors | Readings | |||
|---|---|---|---|---|---|
| Legacy | |||||
| Key On | Red & Brown | 10-13 Volts | |||
| Engine On | Red & Brown | 13-14 Volts | |||
| Key On | Black & Brown | 0-0.3 Volt | |||
| Engine On | Black & Brown | 0.8-1.2 Volts | |||
| Key On | White & Brown | Zero Volts | |||
| Engine On | White & Brown | Zero Volts | |||
| Loyale PFI Turbo | |||||
| Off | Black & Brown | 0-10 Ohms | |||
| Off | Brown & Ground | 0-10 Ohms | |||
| On | Power Wire & Brown | 10 Volts Min. | |||
| On | Signal Wire & Ground | (1) 1-2 Volts | |||
| Loyale TBI | |||||
| Key Off | Black & Ground | 0-10 Ohms | |||
| Key On | Red & Ground | 10 Volts Min. | |||
| Key On | White & Black | (1) .1-.5 Volt | |||
| XT & XT6 1.8L PFI | |||||
| Key Off | Black & Brown | 0-10 Ohms | |||
| Key Off | Brown & Ground | 0-10 Ohms | |||
| Key On | White & Brown | 10 Volts Min. | |||
| XT & XT6 2.7L PFI | |||||
| Key Off | Black & Brown | 0-10 Ohms | |||
| Key Off | Brown & Ground | 0-10 Ohms | |||
| Key On | Red & Brown | 10 Volts Min. | |||
| Key On | White & Brown | (1) 1-2 Volts | |||
|
|||||