Power Circuits (Ignition On)
Turn ignition switch to ON position. Using DVOM, check for battery voltage between control unit power terminals and ground. See CONTROL UNIT POWER TERMINAL IDENTIFICATION table. If battery voltage is not present, check fuse. If fuse is okay, check for an open in wire and a defective ignition switch.
NOTE:
Following procedure does not apply to Justy carbureted.