Solenoid Pull-In Test
Connect jumper wire from negative terminal of 12-volt battery to starter solenoid case. Connect another jumper wire from negative terminal of 12-volt battery to terminal "C". See Fig 1 . Pinion should extend when jumper wire from battery positive terminal is connected to solenoid terminal No. 50. If pinion does not extend as specified, replace starter.