Inhibitor Switch: Adjustment
- Shift the select lever to the N range.
- Loosen the three inhibitor switch securing bolts.
- Insert ST as vertical as possible into the holes in the inhibitor switch lever and switch body.
ST 499267300 STOPPER PIN
- Tighten the three inhibitor switch bolts.
Tightening torque: 3.4+/-0.5 N.m (0.35+/-0.05 kg-m, 2.5+/-0.4 ft-lb)
- Repeat the above checks. If the inhibitor switch is determined to be "faulty", replace it.