Inhibitor Switch: Adjustment
- Loosen the three inhibitor switch securing bolts.
- Shift the select lever to the N range.
- Insert ST as vertical as possible into the holes in the inhibitor switch lever and switch body. ST 499267300 STOPPER PIN
- Tighten the three inhibitor switch bolts.
Tightening torque:
- 3.4 N-m (0.35 kgf-m, 2.5 ft-Ib)
- Repeat the above checks. If the inhibitor switch is determined to be "faulty", replace it.